Estimate capacitance while the motor is running — clamp amps on the cap lead, volts across the can.
Clamp on the wire in series with the capacitor (cap lead).
Meter on the two capacitor terminals.
Shows % vs can rating; ±6% is a common service band.
Live circuit — measure carefully